Emerson Rosemount 3051S Series Reference Manual page 215

Pressure transmitter with foundation fieldbus protocol
Hide thumbs Also See for Rosemount 3051S Series:
Table of Contents

Advertisement

F
Fieldbus Block Information
OUNDATION
October 2016
Parameter
Index
ALERT_KEY
4
MODE_BLK
5
BLOCK_ERR
6
UPDATE_EVT
7
BLOCK_ALM
8
TRANSDUCER
9
_DIRCTORY
TRANSDUCER
10
_TYPE
XD_ERROR
11
COLLECTION_
12
DIRECTORY
PRIMARY_
13
VALUE_TYPE
PRIMARY_
14
VALUE
PRIMARY_
15
VALUE_
RANGE
CAL_POINT_
16
HI
CAL_POINT_
17
LO
CAL_MIN_
18
SPAN
CAL_UNIT
19
SENSOR_TYPE
20
SENSOR_
21
RANGE
SENSOR_SN
22
SENSOR_CAL
23
_METHOD
SENSOR_CAL
24
_ LOC
F
Fieldbus Block Information
OUNDATION
Valid range
Initial value Units Other Description
1-255
0
O/S
0
100
See Table 35
0
and footnote
0-100%
+INF
-INF
0.0
See Table 19
%
See Table 37
0
and footnote4
0-100%
See Table 40
0
NULL
N/A
The identification number of the plant unit.
N/A
The actual, target, permitted, and normal modes of the
block.
E
Read
This parameter reflects the error status associated with
the hardware or software components associated with a
Only
block. it is a bit string, so that multiple errors may be
shown.
N/A
This alert is generated by any change to the staic data.
N/A
The BLOCK_ALM is used for all configuration, hardware,
connection failure or system problems in the block. The
cause of the alert is entered in the subcode field. The
first alert to become active will set the Active status in
the Status attribute. As soon as the Unreported status is
cleared by the alert reporting task, another block alert
may be reported without clearing the Active status, if
the subcode has changed.
N/A
Read
A directory that specifies the number and starting
indicies of the transducers in the transducer block.
Only
E
Read
Identifies the transducer that follows.
Only
E
Read
Provides additional error codes related to transducer
blocks.
Only
N/A
Read
A directory that specifies the number, starting indicies,
and DD Item ID's of the data collections in each
Only
transducer block.
E
The type of measurement represented by the primary
value.
PVR
Read
The measured value and status available to the function
block.
Only
PVR
Read
The high and low range limit values, the engineering
units code and the number of digits to the right of the
Only
decimal point to be used to display the final value.
CU
The highest calibrated value.
CU
The lowest calibrated value.
CU
Read
The minimum calibration span value allowed. This
minimum span information is necessary to ensure that
Only
when calibration is done, the two calibrated points are
not too close together.
E
The Device Description engineering units code index for
the calibration values.
E
The type of sensor connected with the transducer
block.
SR
Read
The high and low range limit values, the engineering
units code and the number of digits to the right of the
Only
decimal point for the sensor.
N/A
Read
The sensor serial number.
Only
E
The method of last sensor calibration.
N/A
The location of the last sensor calibration. This describes
the physical location at which the calibration was
performed.
Reference Manual
00809-0200-4801, Rev DA
205