Table C-3. Definitions of AI Block System Parameters
Parameter
Index
ALERT_KEY
04
BLOCK_ALM
21
BLOCK_ERR
06
CAP_
40
STDDEV
CHANNEL
15
temperature
FIELD_VAL
19
GRANT_
12
DENY
HI_ALM
34
HI_HI_ALM
33
HI_HI_LIM
26
Out_Scale
HI_HI_PRI
25
HI_LIM
28
Out_Scale
HI_PRI
27
IO_OPTS
13
Enable/Disable
208
Available
values
Units
1 – 255
None
N/A
None
N/A
None
> = 0
Seconds
1 = Pressure
None
2 = Housing
0 – 100
Percent
Program
None
Tune
Alarm
Local
N/A
None
N/A
None
(2)
Out_
(2)
Scale
0 – 15
None
(2)
Out_
(2)
Scale
0 – 15
None
Low Cutoff
None
F
OUNDATION
Read/
Default
write
Description
0
Read
The identification number of the plant unit.
This information may be used in the host for
and
sorting alarms, etc.
Write
N/A
Read
The block alarm is used for all configuration,
hardware, connection failure or system
only
problems in the block. The cause of the alert is
entered in the subcode field. The first alert to
become active will set the Active status in the
Status parameter. As soon as the Unreported
status is cleared by the alert reporting task,
another block alert may be reported without
clearing the Active status, if the subcode has
changed.
N/A
Read
This parameter reflects the error status
associated with the hardware or software
only
components associated with a block. It is a bit
string, so that multiple errors may be shown.
0
Read
The time over which the VAR_INDEX is
evaluated.
and
Write
(1)
AI
: Channel
Read
The CHANNEL value is used to select the
measurement value. Refer to the appropriate
= 1
and
device manual for information about the
AI2: Channel
Write
specific channels available in each device.
= 2
You must configure the CHANNEL parameter
before you can configure the XD_SCALE
parameter.
N/A
Read
The value and status from the transducer block
or from the simulated input when simulation is
only
enabled.
N/A
Read
Normally the operator has permission to write
to parameter values, but Program or Local
and
remove that permission and give it to the host
Write
controller or a local control panel.
N/A
Read
The HI alarm data, which includes a value of
the alarm, a timestamp of occurrence and the
only
state of the alarm.
N/A
Read
The HI HI alarm data, which includes a value of
the alarm, a timestamp of occurrence and the
only
state of the alarm.
N/A
Read
The setting for the alarm limit used to detect
the HI HI alarm condition.
and
Write
1
Read
The priority of the HI HI alarm.
and
Write
N/A
Read
The setting for the alarm limit used to detect
the HI alarm condition.
and
Write
1
Read
The priority of the HI alarm.
and
Write
Disable
Read
Allows the selection of input/output options
used to alter the PV. Low cutoff enabled is the
and
only selectable option.
Write