F
Fieldbus Block Information
OUNDATION
October 2016
Table C-1. Resource Block Parameters
Parameter
Index
FAULT_STATE
28
SET_FSTATE
29
CLR_FSTATE
30
MAX_NOTIFY
31
LIM_NOTIFY
32
CONFIRM_
33
TIME
WRITE_LOCK
34
UPDATE_EVT
35
BLOCK_ALM
36
ALARM_SUM
37
ACK_OPTION
38
WRITE_PRI
39
WRITE_ALM
40
ITK_VER
41
DISTRIBUTOR
42
DEV_STRING
43
XD_OPTION
44
FB_OPTION
45
DIAG_OPTION
46
F
Fieldbus Block Information
OUNDATION
Valid range
Initial value Units Other Description
1: Clear
2: Active
1: Off
1
2: Set
1: Off
1
2: Clear
7
0 to
MAX_NOTIF
MAX_NOTIFY
Y
640000
1: Unlocked
1
2: Locked
0: Auto Ack
0
Disabled
1: Auto Ack
Enabled
0 - 15
0
set by FF
5
"Rosemount"
0X26
0 to
0
0xFFFFFFFF
E
Read
Condition set by loss of communication to an output
block, fault promoted to an output block or a physical
Only
contact. When Fault State condition is set, then output
function blocks will perform their FSTATE actions.
E
Allows the Fault State condition to be manually initiated
by selecting Set.
E
Writing a Clear to this parameter will clear the device
fault state if the field condition, if any, has cleared.
N/A
Read
Maximum number of unconfirmed notify messages
possible.
Only
N/A
Maximum number of unconfirmed alert notify messages
allowed.
1/32
The time the resource will wait for confirmation of
receipt of a report before trying again. Retry will not
millise
happen when CONFIRM_TIME=0.
c
E
If set, no writes from anywhere are allowed, except to
clear WRITE_LOCK. Block inputs will continue to be
updated.
N/A
This alert is generated by any change to the staic data.
N/A
The BLOCK_ALM is used for all configuration, hardware,
connection failure or system problems in the block. The
cause of the alert is entered in the subcode field. The first
alert to become active will set the Active status in the
Status attribute. As soon as the Unreported status is
cleared by the alert reporting task, another block alert
may be reported without clearing the Active status, if
the subcode has changed.
N/A
The current alert status, unacknowledged states,
unreported states, and disabled states of the alarms
associated with the function block.
N/A
Selection of whether alarms associated with the block
will be automatically acknowledged.
N/A
Priority of the alarm generated by clearing the write lock.
N/A
This alert is generated if the write lock parameter is
cleared.
N/A
Read
Major revision number of the interoperability test case
used in certifying this device as interoperable. The
Only
format and range are controlled by the Fieldbus
Foundation.
E
Read
Reserved for use as distributor ID. No Foundation
enumerations defined at this time.
Only
N/A
This is used to load new licensing into the device. The
value can be written but will always read back with a
value of 0.
E
Read
Indicates which transducer block licensing options are
enabled.
Only
E
Read
Indicates which function block licensing options are
enabled.
Only
E
Read
Indicates which diagnostics licensing options are
enabled.
Only
Reference Manual
00809-0200-4801, Rev DA
201