Overview; Basic Configuration Parameters; Configuration Tools - Emerson Rosemount 5402 Reference Manual

Level transmitter, two-wire non-contacting radar
Hide thumbs Also See for Rosemount 5402:
Table of Contents

Advertisement

Configuration
October 2018
5.2

Overview

The configuration of a Rosemount
task. If the transmitter is pre-configured at the factory according to ordering specifications in the
Configuration Data Sheet, no further basic configuration is required, unless tank conditions have
changed.
The Rosemount 5400 supports a set of advanced configuration options that can be used to handle
special tank conditions and applications. For further information on advanced configuration options, see
Appendix C: Advanced
5.2.1

Basic configuration parameters

The basic configuration includes parameters for a standard configuration which is sufficient in most
cases. The basic configuration comprises the following items:
Measurement Units
Tank Configuration
- Tank Geometry
- Environment
- Volume
Analog Output
Echo Tuning: see
(ATC) False Echo Registration.
5.2.2

Configuration tools

There are several tools available for basic configuration of a Rosemount 5400:
RRM. Note that RRM is required for advanced configuration features.
See
Rosemount 5400.
Rosemount Field Communicator.
See
DTM
configuration in, for instance, Yokogawa Fieldmate/PRM, E+H FieldCare
AMS Suite software (for HART
See
DeltaV
See
using DeltaV.
Other tools that support EDDL functionality.
RRM is a user-friendly, Windows
configuration Wizard, logging, and extensive online help.
To communicate with the transmitter using RRM, a HART modem (part number 03300-7004-0001 or
03300-7004-0002) or a F
required. For F
Communication Manager software (see
page
100
Configuration.
"Echo tuning" on page 109
"Basic configuration using RRM" on page 110
"Configuration using a Field Communicator" on page 129
(compliant with version 1.2 of the FDT
"Basic configuration using AMS Suite" on page 133
(only for F
OUNDATION
"Configuration using DeltaV" on page 134
OUNDATION
Fieldbus communication you will also need the National Instruments
OUNDATION
113).
5400 Level Transmitter is normally a simple and straightforward
for more information on Amplitude Threshold Curve
for information on using RRM to configure the
®
/DTM specification) is also available supporting
®
).
Fieldbus).
for information on configuring the Rosemount 5400
based software package that includes waveform plots, offline/online
Fieldbus modem (part number 03095-5108-0001 for PCMCIA) is
"Installing the RRM software for F
Reference Manual
00809-0100-4026, Rev KC
for the Field Communicator Menu Tree.
, and PACTware
for information on configuring AMS Suite.
OUNDATION
Fieldbus" on
Configuration

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5401Rosemount 5400

Table of Contents