Specifications and Reference Data
October 2016
Product certifications
E1
ATEX Flameproof
I1
ATEX Intrinsic Safety
IA
ATEX FISCO Intrinsic Safety; for F
N1
ATEX Type n
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
ND
ATEX Dust
E5
FM Explosion-proof, Dust Ignition-proof
I5
FM Intrinsically Safe, Division 2
IE
FM FISCO Intrinsically Safe; for F
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
E6
CSA Explosion-proof, Dust Ignition-proof, Division 2
I6
CSA Intrinsically Safe
IF
CSA FISCO Intrinsically Safe; for F
K6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6)
E7
IECEx Flameproof, Dust Ignition-proof
I7
IECEx Intrinsic Safety
IG
IECEx FISCO Intrinsic Safety; for F
N7
IECEx Type n
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7, and N7)
E2
INMETRO Flameproof
I2
INMETRO Intrinsic Safety
K2
INMETRO Flameproof, Intrinsic Safety
ATEX and CSA Flameproof, Intrinsically Safe, Division 2 (combination of E1, E6, I1, and I6)
KA
Note: Only available on Housing Style codes IA, IJ, 2A, 2J, 2E, 2M, 3A, or 3J.
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5, E6, I5, and I6)
KB
Note: Only available on Housing Style codes IA, IJ, 2A, 2J, 2E, 2M, 3A, or 3J.
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5, and I1)
KC
Note: Only available on Housing Style codes IA, IJ, 2A, 2J, 2E, 2M, 3A, or 3J.
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, E6, E1, I5, I6, and I1)
KD
Note: Only available on Housing Style codes IA, IJ, 2A, 2J, 2E, 2M, 3A, or 3J.
(7)
Digital display
M5
PlantWeb LCD display
Remote mount LCD display and interface, no cable; PlantWeb housing, SST bracket, requires 4-20 mA / HART output
(8)
M7
Note: See the Rosemount 3051S
additional information.
(8)(9)
M8
Remote mount LCD display and interface, 50 ft. (15 m) cable; SST bracket, requires 4-20 mA / HART output
(8)(9)
M9
Remote mount LCD display and interface, 100 ft. (31 m) cable; SST bracket, requires 4-20 mA / HART output
Specifications and Reference Data
Fieldbus Protocol only
OUNDATION
Fieldbus Protocol only
OUNDATION
Fieldbus Protocol only
OUNDATION
Fieldbus Protocol only
OUNDATION
Reference Manual
for cable requirements. Contact an Emerson representative for
Reference Manual
00809-0200-4801, Rev DA
151