Emerson Rosemount 3051S Series Reference Manual page 212

Pressure transmitter with foundation fieldbus protocol
Hide thumbs Also See for Rosemount 3051S Series:
Table of Contents

Advertisement

Reference Manual
00809-0200-4801, Rev DA
Table C-1. Resource Block Parameters
Parameter
Index
MISC_OPTION
47
RB_SFTWR_
48
REV_MAJOR
RB_SFTWR_
49
REV_MINOR
RB_SFTWR_
50
REV_BUILD
RB_SFTWR_
51
REV_ALL
HARDWARE_
52
REV
OUTPUT_
53
BOARD_SN
FINAL_ASSY_
54
NUM
DETAILED_
55
STATUS
SUMMARY_
56
STATUS
MESSAGE_
57
DATE
MESSAGE_
58
TEXT
SELF_TEST
59
DEFINE_
60
WRITE_LOCK
SAVE_CONFIG
61
_NOW
202
Valid range
Initial value Units Other Description
set by build
set by build
set by build
set by build
3
set by mfgr
set by mfgr
See Table 22
0:Uninitialized
0
1: No repair
needed.
2: Repairable
3: Call service
center
0
spaces
0: Uninitialized
1
1: No test
2: Self test
0: Uninitialized
1
1: Everything
Locked
2: Only
physical device
locked
0: Uninitialized
1
1: No save
2: Burn
EEPROM with
latest values
F
OUNDATION
E
Read
Indicates which miscellaneous licensing options are
enabled.
Only
N/A
Read
Major revision of software that the resource block was
created with.
Only
N/A
Read
Minor revision of software that the resource block was
created with.
Only
N/A
Read
Build of software that the resource block was created
with.
Only
N/A
Read
The string will contains the following fields:
Major rev: 1-3 characters, decimal number 0-255
Only
Minor rev: 1-3 characters, decimal number 0-255
Build rev: 1-5 characters, decimal number 0-255
Time of build: 8 characters, xx:xx:xx, military time
Day of week of build: 3 characters, Sun, Mon, ...
Month of build: 3 characters, Jan, Feb.
Day of month of build: 1-2 characters, decimal number
1-31
Year of build: 4 characters, decimal
Builder: 7 characters, login name of builder
N/A
Read
Hardware revision of that hardware that has the resource
block in it.
Only
N/A
Read
Output board serial number.
Only
N/A
Read
The same final assembly number placed on the neck
label.
Only
E
Read
Indicates the state of the transmitter.
Only
E
Read
An enumerated value of repair analysis.
Only
N/A
Date associated with the MESSAGE_TEXT parameter
N/A
Used to indicate changes made by the user to the
device's installation, configuration, or calibration.
E
Used to self test the device. Tests are device specific.
E
Allows the operator to select how WRITE_LOCK behaves.
The initial value is "lock everything". If the value is set to
"lock only physical device" then the resource and
transducer blocks of the device will be locked but
changes to function blocks will be allowed.
E
Allows the user to optionally save all non-volatile
information immediately.
Fieldbus Block Information
October 2016
F
Fieldbus Block Information
OUNDATION

Advertisement

Table of Contents
loading

Table of Contents