Reference Manual
00809-0200-4801, Rev DA
13.
Available with output code A only. Available approvals are FM Intrinsically Safe; Nonincendive (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety
(option code I1), or IECEx Intrinsic Safety (option code I7). Contact an Emerson Process Management representative for additional information.
14.
Long-Life Power Module must be shipped separately, order Power Module 701PBKKF.
15.
Option HR7 configures the HART output to HART Revision 7. This option requires the selection of the Advanced Diagnostics (DA2) option. The device with this option can
be field configured to HART Revision 5 or 7 if desired.
16.
Requires PlantWeb housing and output code A. Includes Hardware Adjustments as standard.
17.
Requires Rosemount Engineering Assistant to configure.
18.
For process connection option code A11, the mounting bracket must be ordered as part of the manifold model number.
19.
Not available with output code F.
20.
Not available with output code X.
21.
Not available with housing style codes 00, 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
22.
Not available with process connection option code A11.
23.
Requires PlantWeb housing and Hardware Adjustments option code D1. Limited availability depending on transmitter type and range. Contact an Emerson Process
Management representative for additional information.
24.
This assembly is included with options EP, KP, E1, N1, K1, ND, E4, E7, N7, K7, E2, E3, KA, KC, KD, IA, IB, IE, IF, IG, KG, T1, K2, N3, EM, and KM.
25.
Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
26.
Valid when SuperModule Platform and housing have equivalent approvals.
27.
Not available with M20 or G
28.
Only available on differential and gage measurement types. Silicone fill fluid is standard.
29.
Bolts are not considered process wetted. In instances where NACE MR0175/ISO 15156 and NACE MR0103 conformance is required for bolting, L7 is the recommended
bolting option.
30.
Not available with Housing code 7J.
31.
Not available with output code F, option code DA2, or option code QT.
32.
See the Rosemount 3051S
Reference Manual
33.
P1 is not available with 3051S_CA0.
34.
When assembled to remote diaphragm seal system using B11 or B12process connections, the maximum working pressure of the system may be limited by the rating of
the Rosemount 1199 Seal System selected.
35.
Requires 316L SST, Alloy C-276, or Gold-plated 316L SST diaphragm material, assemble to Rosemount 305 integral manifold or DIN-compliant traditional flange process
connection, and bolting option L8. Limited to Pressure Range (Differential), ranges 2A – 5A.
36.
Not available with output code F or X. Not available with housing code 7J.
37.
Not available with Housing code 00, 5A, 5J, or 7J.
38.
The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, IE, IF, IG, and KG.
39.
Requires 316L SST diaphragm material, glass-filled PTFE O-ring (standard), and Process Connection code E12 or F12.
40.
Not available with Housing code 00, 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe; Nonincendive (option code I5) or FM FISCO
Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009. Suitable for use with all IS approvals (I1, I2, I3, I5, I6, I7, IA, IB, IE, IF, IG, IP,
IM, KG).
41.
NACE compliant wetted materials are identified by <HotXRef_7pt>Footnote 5.
132
1
/
conduit entry size.
2
for cable requirements. Contact an Emerson Process Management representative for additional information.
Specifications and Reference Data
Specifications and Reference Data
October 2016