00809-0200-4801, Rev DA
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the enclosure
to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient temperature range of the apparatus and capable of
withstanding a 7 J impact test.
4. The Rosemount 3051S SuperModule must be securely
screwed in place to maintain the ingress protection of the
enclosure.
I7
IECEx Intrinsic Safety
Certificate: IECEx BAS 04.0017X
Standards: IEC 60079-0: 2011, IEC 60079-11:2011
Markings: Ex ia IIC T4 Ga, T4(–60 °C
Model
SuperModule
3051S...A; 3051SF...A;
3051SAL...C
3051S...F; 3051SF...F
3051S ...A...M7, M8, or M9;
3051SF ...A...M7, M8, or M9;
3051SAL...C... M7, M8, or M9
3051SAL or 3051SAM
3051SAL...M7, M8, or M9
3051SAM...M7, M8, or M9
RTD Option for 3051SF
Special Conditions for Safe Use (X):
1. The Rosemount 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500 V test as
defined in Clause 6.3.13 of EN 60079-11:2012. This must be
taken into account during installation.
2. The terminal pins of the Rosemount 3051S SuperModule
must be provided with a degree of protection of at least IP20
in accordance with IEC/EN 60529.
3. The Rosemount 3051S enclosure may be made of aluminum
alloy and given a protective polyurethane paint finish;
however, care should be taken to protect it from impact or
abrasion if located in a zone 0 area.
I7
IECEx Intrinsic Safety – Group I - Mining (I7 with Special
A0259)
Certificate: IECEx TSA 14.0019X
Standards: IEC 60079-0:2011, IEC 60079-11:2011
Markings: Ex ia I Ma (–60 °C
Model
SuperModule
3051S...A; 3051SF...A;
3051SAL...C
3051S...F; 3051SF...F
3051S ...A...M7, M8, or M9;
3051SF ...A...M7, M8, or M9;
3051SAL...C... M7, M8, or M9
3051SAL or 3051SAM
162
T
+70 °C)
a
U
I
P
C
i
i
i
i
30 V
300 mA
1.0 W
30 nF
30 V
300 mA
1.0 W
12 nF
30 V
300 mA
1.3 W
0
30 V
300 mA
1.0 W
12 nF
30 V
300 mA
1.0 W
12 nF
30 V
300 mA
1.0 W
12 nF
5 V
500 mA
0.63 W
N/A
T
+70 °C)
a
U
I
P
C
i
i
i
i
30 V
300 mA
1.0 W
30 nF
30 V
300 mA
1.0 W
12 nF
30 V
300 mA
1.3 W
0
30 V
300 mA
1.0 W
12 nF
30 V
300 mA
1.0 W
12 nF
Model
3051SAL...M7, M8, or M9
3051SAM...M7, M8, or M9
RTD Option for 3051SF
Special Conditions for Safe Use (X):
1. If the apparatus is fitted with optional 90 V transient
suppressor, it is not capable of withstanding the 500 V
insulation test required by Clause 6.3.13 of
IEC60079-11:2011. This must be taken into account when
installing the apparatus.
2. It is a condition of safe use that the above input parameters
shall be taken into account during installation.
3. It is a condition of manufacture that only the apparatus fitted
L
with housing, covers and sensor module housing made out
i
of stainless steel are used in Group I applications.
0
IG
IECEx FISCO
0
Certificate: IECEx BAS 04.0017X
0
Standards: IEC 60079-0:2011, IEC 60079-11:2011
60 H
Markings: Ex ia IIC T4 Ga, T4(–60 °C
Parameter
33 H
Voltage U
93 H
i
Current I
i
N/A
Power P
i
Capacitance C
Inductance L
Special Conditions for Safe Use (X):
1. The Rosemount 3051S Transmitters fitted with transient
protection are not capable of withstanding the 500 V test as
defined in Clause 6.3.13 of EN 60079-11:2012. This must be
taken into account during installation.
2. The terminal pins of the Rosemount 3051S SuperModule
must be provided with a degree of protection of at least IP20
in accordance with IEC/EN 60529.
3. The Rosemount 3051S enclosure may be made of aluminum
alloy and given a protective polyurethane paint finish;
however, care should be taken to protect it from impact or
abrasion if located in a zone 0 area.
L
i
0
0
0
60 H
33 H
Product Certifications
U
I
i
i
30 V
300 mA
1.0 W
5 V
500 mA
0.63 W
T
+70 °C)
a
FISCO
17.5 V
380 mA
5.32 W
0
i
0
i
Product Certifications
October 2016
P
C
L
i
i
i
93 H
12 nF
N/A
N/A