Emerson Rosemount 3051S Series Reference Manual page 216

Pressure transmitter with foundation fieldbus protocol
Hide thumbs Also See for Rosemount 3051S Series:
Table of Contents

Advertisement

Reference Manual
00809-0200-4801, Rev DA
Parameter
Index
SENSOR_CAL
25
_DATE
SENSOR_CAL
26
_WHO
SENSOR_
27
ISOLATOR_
MTL
SENSOR_FILL_
28
FLUID
SECONDARY_
29
VALUE
SECONDARY_
30
VALUE_UNIT
TB_DETAILED
31
_STATUS
FACTORY_CAL
32
_RECALL
MODULE_
33
TYPE
SENSOR_CAL
34
_TYPE
FLANGE_TYPE
35
FLANGE_MTL
36
REM_SEAL_
37
NUM
REM_SEAL_
38
TYPE
REM_SEAL_
39
ISO_MTL
REM_SEAL_
40
FILL
O_RING_MTL
41
DRAIN_VENT_
42
MTL
PRIMARY_
43
VALUE_
DAMPING
206
Valid range
Initial value Units Other Description
0
See Table 19
and footnote4
1: No Recall
1
2: Recall
3: Save factory
trim
252:
Unknown
See Table 39
252:
Unknown
See Table 50
0
See Table 49
0
See Table 45
0
See Table 46
0
See Table 44
0
See Table 43
0
See Table 48
0
See Table 47
0
0.0f
0.0
F
OUNDATION
N/A
The date of the last sensor calibration. This is intended
to reflect the calibration of that part of the sensor that is
usually wetted by the process.
N/A
The name of the person responsible for the last sensor
calibration.
E
Read
Defines the construction material for the isolating
diaphragms.
Only
E
Read
Defines the type of fill fluid used in the sensor.
Only
SVU
Read
The secondary value, related to the sensor.
Only
E
The engineering units to be used with the
SECONDARY_VALUE.
N/A
Read
Indicates the state of the transmitter. The parameter
contains specific codes relating to the transducer block
Only
and the pressure sensor specifically.
E
Recalls the sensor calibration set at the factory.
If the device is in "factory mode", a value of 3 may be
entered to save the current trim values into a factory
area of NV memory to be used for factory calibration
recall
E
Read
Indicates the type of sensor module.
Only
E
The type of last sensor calibration.
N/A
Indicates the type of flange that is attached to the
device. See Flange Type Codes.
N/A
Indicates the type of material that the flange is made of.
See Flange Material Codes.
N/A
Indicates the number of remote seals that are attached
to the device. See Remote Seal Number Codes.
N/A
Indicates the type of remote seals that are attached to
the device. See Remote Seal Type Codes.
N/A
Indicates the type of material that the remote seal
isolators are made of. See Remote Seal Isolator Material
Codes.
N/A
Indicates the type of fill fluid used in the remote seals.
See Remote Seal Fill Fluid Codes.
N/A
Indicates the type of material that the flange o-rings are
made of. See O-ring Material Codes.
N/A
Indicates the type of material that the drain vents on the
flange are made of. See Drain Vent Material Codes.
Sec.
Time constant of a single exponential filter for the PV, in
seconds.
Fieldbus Block Information
October 2016
F
Fieldbus Block Information
OUNDATION