C
AUTION
If using forced air to clean the sensors, do NOT turn the can of forced air upside down or tip it
sideways more than 40 degrees while using. The extension tube can be bent so as to avoid
having to tip the can.
The feeder sensor detects paper on the feeder table. Dust and small particles of paper may build
up on the sensor, causing the feeder table not to lower after the last page fed. Regular cleaning
of the feeder sensor will reduce this problem.
Separator
Roller Door
Item(s) Needed
•
Blower Brush
•
Forced Air (optional, not supplied)
C
AUTION
Avoid using any type of cotton swab or any item that may leave lint behind. These types of
cleaning items can cause further problems with sensors functioning properly.
W
ARNING
Make sure to power OFF the scanner before applying forced air to the sensors.
S008769 Rev A
Cork Pad
Feeder Table
C
LEANING THE
Feeder Sensor
F
S
EEDER
ENSOR
75