Glass Flat
Fastening Clips (2)
Left Side
-
Locate the 2 fastening clips that secure the glass flat in the scanner. They are located
along the back, horizontal edge of the glass flat (closest to the back of the scanner), one
on the far left side and the other on the far right. Gently pull the clips with your index finger
towards the front of the scanner to release the glass flat from its position
-
Holding the left and right sides of the frame around the glass flat, lift the back half of the
glass flat up and slide the entire assembly towards the back of the scanner to release the
glass flat's frame from the transport (there are 5 guides attached to the glass flat's frame
that sit beneath the transport tray)
4. Spray the Roller and Glass Cleaner on the Lint Free Cloth, taking care that any overspray
does not fall inside the scanner
5. Wipe down the both sides of the glass flat, taking care not to touch the cleaned glass with your
fingers
6. Re-insert the cleaned glass flat into the scanner
-
Hold the frame of the glass flat on the left and right side so that the fastening clips (2) are
on the back side of the glass flat (side closest to the back of the scanner). Position the
glass flat over the top and slightly behind the opening in the transport tray, centering the
glass flat over the opening
-
Slide the guides (5) under the transport tray towards the feeder table
Back of scanner
Fastening
Clips (2)
70
Frame
Bottom (back page) Tray - Inserting the Glass Flat
(as viewed from left side)
Glass Flat
Guides (5)
Five guides slide underneath the transport tray
Right Side
Glass
Front of Scanner