Initial Press Stroke; Acknowledge Protected Field Modes - Pilz PSENvip RL D P Set Operating Manual

Table of Contents

Advertisement

Operation
8.2.3

Initial press stroke

When the initial press stroke occurs after the machine is switched on, a function test must
be carried out on the PSENvip, using the test piece.
}
Set standard protected field mode.
}
Operate the foot switch to initiate the press stroke.
}
Use the test piece to carry out the function test (see section entitled "Function test of the
safety device").
8.2.4

Acknowledge protected field modes

The protected field modes are shown on the display as follows:
Standard
An acknowledgement button must be operated to initiate a press stroke with a reduced pro-
tected field.
Operating Manual PSENvip RL D P Set
1001641-EN-09
Box bending
INFORMATION
The display of the available protected field modes also depends on the se-
lected tool class. Please refer also to the section entitled "Protected field
modes", under "Function Description".
WARNING!
Risk of injury due to reduced protected field!
Around the bending line there is an increased risk of crushing and trapping
of fingers or hands because the front segments of the protected field are
blanked.
Make sure that the workpiece is handled correctly (see Chapter "Safety").
WARNING!
Risk of injury due to reduced protected field!
Around the bending line there is an increased risk of crushing and trapping
of fingers or hands because the front and rear segments of the protected
field are blanked.
Make sure that the workpiece is handled correctly.
Back gauge
Box bending with
back gauge
| 87