Function description
2
Upper tool continues moving for
the overrun distance. Protected
field interrupted Object is re-
moved Protected field cleared.
Press stroke can be resumed.
4.3

Overrun

The max. overrun is a press brake variable that will depend on the machine type. Once the
closing movement has stopped, the max. overrun must not be exceeded.
The overrun is entered during configuration via the keypad on the PSENvip receiver.
Normally, the factory-assigned overrun is sufficient and does not have to be configured.
Operating Manual PSENvip RL D P Set
1001641-EN-09
INFORMATION
Please refer to chapter 11, "Technical Details", for more information about
the input area of the overrun.
Details on how to enter the overrun are described in Chapter 7, "Commis-
sioning", section entitled "Enter overrun".
WARNING!
The protected field is reduced when the overrun is too low
A reduced protected field may lead to serious injury and death.
If you require a different overrun path than the factory-set path, then use the
value indicated by the manufacturer on the nameplate of the press brake, or
a higher value. If you enter a lower value for the overrun, the protected field
will also be reduced to an unpermitted level.