Function Test Of The Safety Device; Test During Initial Commissioning; Test After Machine Modification - Pilz PSENvip RL D P Set Operating Manual

Table of Contents

Advertisement

Commissioning
7.5.1

Function test of the safety device

A test piece in accordance with Annex H of EN 12622 is used for the function test.
Fig.: Test piece in accordance with EN 12622
The function test on the protective equipment using the test piece involves:
}
The detection of objects
}
Overrun measurement
7.5.1.1

Test during initial commissioning

The machine manufacturer must perform a function test on the safeguard before putting the
press brake into service. During this test the press brake must be fully configured with the
upper tool (maximum weight). The test should be performed at maximum closing speed.
7.5.1.2

Test after machine modification

The safeguards should be tested after each machine modification (e.g. after entering the
overrun, after a tool change, after changes to the press controller). The tests should be the
same as those carried out during initial commissioning.
Changing the PSENvip or swapping PSENvip components should also be regarded as a
modification.
You must comply with the requirements of the applicable national regulations.
Operating Manual PSENvip RL D P Set
1001641-EN-09
WARNING!
The press brake must be shut down immediately if the test reveals a
fault!
Failure to comply could result in a hazardous situation, which could lead
to serious injury and death.
In this case, have the safety equipment checked by qualified staff.
10
15
INFORMATION
The test during initial commissioning may only be carried out by qualified
personnel.
50 x 50
35
Ø 14
| 82

Advertisement

Table of Contents
loading

Table of Contents