Commissioning
Fig.: Tool change menu
}
1: Tool centre point
}
2: Range bar
}
3: Adjustment line
}
4: Central and rear bending line
}
5:
}
6:
}
7: Detected tool class
The adjustment line is automatically tracked to the tool centre point.
The vertical position of the tool centre point must be within the range bar. Once the adjust-
ment line is at the top or bottom of the range bar, the following symbol appears:
If the
by the transmitter:
}
Check that the transmitter and receiver are aligned correctly. The illuminated target area
must completely envelop the receiver. If necessary, realign the transmitter (see section
entitled "Align transmitter").
}
Remove any potential contamination on the lens of the transmitter or receiver.
The adjustment has been carried out correctly when none of the symbols appear:
}
Finish the adjustment using the <ENTER> key.
The PSENvip prompts you to confirm that you accept the new tool data:
}
Within 3 seconds, press the key
}
You can exit the menu at any time without confirming by pressing <ESC>. In this case,
the previous tool data will be retained.
Operating Manual PSENvip RL D P Set
1001641-EN-09
SYSTEM OK OSSD OFF
TOOL CHANGE
No tool identified or vertical position of tool centre point outside of the range bar
Receiver insufficiently lit by transmitter
symbol appears on the display, there is a problem with the lighting of the receiver
Tool class 1
.
À