Standard Interrupted Press Stroke - Pilz PSENvip RL D P Set Operating Manual

Table of Contents

Advertisement

Function description
4.2.2

Standard interrupted press stroke

It is necessary to distinguish between
}
Interruption of the advance measuring field
and
}
Side intervention with full protected field and reduced protected field during the dynamic
muting
Interruption of the advance measuring field
1
Downward movement
Object interrupts advance meas-
uring field, starts dynamic muting
OSSD1/OSSD2 = 1
Mute1/Mute2 = 1 -> 0
Safety system initiated the stop-
ping of the press, measuring
field was not interrupted in the
expected position (pinch point)
2
Upper tool continues moving for
the overrun distance. Protected
field interrupted Object is re-
moved Protected field cleared.
Press stroke can be resumed.
Side intervention with full protected field or reduced protected field during the dy-
namic muting
1
Object interrupts the protected
field to the side:
OSSD1/OSSD2= 1 -> 0
Mute1/Mute2 = 1
Safety system initiates the stop-
ping of the press stroke
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 24