Function Test Using The Test Piece - Pilz PSENvip RL D P Set Operating Manual

Table of Contents

Advertisement

Commissioning
7.5.1.5

Function test using the test piece

Function test using the test rod (= test piece handle)
}
Move the test rod (14 mm diameter) slowly along the whole detection zone at the centre
point of the upper tool.
Fig.: Function test using test rod
The test rod must be detected along the whole length of the detection zone.
The OSSDs switch to the OFF state. The LED on the receiver lights up red.
Function test with 10 mm and 15 mm test piece
}
Position the 10 mm high section of the test piece on top of the lower tool.
}
Initiate a press stroke.
Fig.: Function test using test piece
Operating Manual PSENvip RL D P Set
1001641-EN-09
INFORMATION
The following tests must be run on the left- and right-hand end as well as in
the centre of the press brake:
- During initial commissioning: 10 times
- During the daily check and during a tool change: 3 times
| 84