Technical details
Environmental data
(EN 60068-2-6)
Shock
(EN 60068-2-29)
EMC
Mechanical data
Dimensions (H x W x D)
Transmitter
Receiver
Weight
Transmitter
Receiver
The standards valid on 2010-03 apply.
Safety characteristic data
Unit
Operating
mode
PSENvip
---
All the units used within a safety function must be considered when calculating the safety
characteristic data.
Operating Manual PSENvip RL D P Set
1001641-EN-09
Amplitude: 0.35 mm
20 cycles per axis
10 g, 16 ms
EN 61000-6-4, EN 61496-1
115.5 mm x 112 mm x 168 mm
115.5 mm x 112 mm x 228 mm
1700 g
2900 g
EN ISO
EN 954-1
13849-1
Category
PL
PL e (Cat. 4)
Cat. 4
EN IEC 62061
SIL CL
PFH [1/h]
SIL CL 3
5.08E-9
(T = 40 °C)
t
[year]
M
20