System Cycle For Back Gauge Press Stroke - Pilz PSENvip RL D P Set Operating Manual

Table of Contents

Advertisement

Function description
7
Status
Foot switch
System-Init
OSSD
Protected field
Mute 1/2
Dynamic muting
8
Status
Foot switch
System-Init
OSSD
Protected field
Mute 1/2
Dynamic muting
Continue with step 1
4.7.3

System cycle for back gauge press stroke

Inputs on the PSENvip receiver:
}
Protected field mode 1 = 1
}
Protected field mode 2 = 0
}
Acknowledgement of reduced protected field = Press pushbutton and then release
The system cycle is the same as for box bending. Please note that with back gauge protec-
ted field mode, the rear segments of the protected field are blanked.
Operating Manual PSENvip RL D P Set
1001641-EN-09
Press is at bottom dead
centre
1
0
0
Interrupted
0
Inactive
Upward movement
Advance measuring field
is cleared
1
Generally, the press
travels up automatically,
the operator can release
the foot switch.
1
1 or 0
Free or interrupted
0 - > 1
Inactive
v = 0
v < 0
BDC