Function description
4.6.1

Standard interrupted press stroke

The press stroke must be interrupted if
an object interrupts the advance measuring field,
}
there is side intervention into the protected field,
}
there is side intervention into a reduced protected field during dynamic muting.
}
Procedure when advance measuring field is interrupted
Downward movement:
Object interrupts advance meas-
uring field, starts dynamic muting
OSSD signal: 1
Mute signal: becomes 0
LED OSSD: lights
LED Mute: goes out
Control system initiates the stop-
ping of the press, measuring
field was not interrupted in the
expected position (pinch point)
Upper tool continues moving for
the overrun distance, protected
field interrupted. Object is re-
moved. Protected field cleared.
Press stroke can be resumed.
Operating Manual PSENvip R, PSENvip R LR,PSENvip E