Overview - Pilz PSENvip RL D P Set Operating Manual

Table of Contents

Advertisement

Overview

2
Overview
The PSENvip is a camera-based protection and measuring system (electrosensitive pro-
tective equipment) for press brakes. It consists of a transmitter and receiver. The PSENvip
monitors the detection zone between the transmitter and receiver below the moving upper
tool.
Transmitter
}
Generates parallel beam
}
2 inputs for controlling the light source
Receiver
}
Evaluates the light generated by the transmitter
}
Display for the operating statuses and inputs
}
Membrane keypad for operating the menus and for inputs
}
Max. distance between transmitter and receiver: 10 m
Inputs
}
1 input for setup mode
}
1 input for signalling when the press brake is at top dead centre
}
2 inputs for controlling the protected field mode:
Protected field can be adapted to a range of bending functions: full protected field, re-
duced protected field for box bending and lower tools with back gauge
}
1 input for acknowledging the protected field mode
Outputs
}
2 output signal switching devices (OSSD) for signalling the status of the protected field
(clear or interrupted)
}
2 outputs for signalling that PSENvip is in dynamic muting
Some inputs and outputs are used for communication with the safety system during the
system status TEST:
}
Register tool class on safety system
}
Approve tool class for PSENvip
LED indicators for
}
Status of OSSDs
Operating statuses
}
Adjustment for initial commissioning
}
Tool change
}
Diagnostics
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 8