Error Messages - Pilz PSENvip RL D P Set Operating Manual

Table of Contents

Advertisement

Diagnostics and Troubleshooting
9.2

Error messages

Error messages appear on the display as soon as an error occurs.
Fig.: Error messages on the display
Error message on the
display
Not relevant to
the user
Press ESC to proceed
Operating Manual PSENvip RL D P Set
1001641-EN-09
Error message
Not relevant to the user
Press ESC to continue
Internal error
Internal error
STOP
STOP
Wiring error
Wiring error
Initial commissioning
Initial
commissioning
No valid data detected (tool
No valid data
detected (tool and/
and/or overrun)
or overrun)
No adjustment performed
No adjustment
performed after
after tool change
tool change
ERROR
OSSD OFF
Error in the
optical system
NORMAL OPERATION
Remedy
1.) Acknowledge the error by
pressing ESC
1.) Restart the PSENvip: Switch
supply voltage off and then on
again
2.) Change the receiver
1.) Restart the PSENvip: Switch
supply voltage off and then on
again
2.) Ensure that the wiring is cor-
rect
3.) Rectify short circuit between
the inputs and/or outputs and 0
V / 24 V
4) Change the receiver
1.) Please contact Pilz
1.) Enter overrun and/or make
adjustment during tool change
1.) Make adjustment during tool
change
| 92