Wiring
6.2.2

Transmitter

The top of the transmitter has a 4-pin M12 connector.
Fig.: Pin assignment of transmitter
The transmitter is connected via a 4-core cable. The cable ends of the Pilz ready-made
cable are colour-coded. Please refer to the table below for the coding details.
Pin assignment of M12 connector X3 on the transmitter
Pin no.
1
2
3
4
Shield
6.2.3

Supply voltage

The supply voltage is fed to the receiver and transmitter via the 8-core / 4-core connection
cable.
6.2.4

Connection between transmitter and receiver

The signals TRM_ON and TRM_SYNC are routed via the control cabinet.
Operating Manual PSENvip RL D P Set
1001641-EN-09
Designation
24 V DC
TRM_SYNC
0 V
TRM_ON
Cable shielding
4
3
2
1
Description
Input, 24 V DC supply voltage
Input, signal to control the intensity of
the light source
Input, 0 V supply voltage
Input, signal to switch the light source
on and off
Colour
brown
white
blue
Black