Wiring
EMC
}
Avoid interference (e.g. from motors, power lines) by laying cables in a way that is EMC-
compliant.
Inputs on the receiver
}
The inputs Protected field mode 1/Protected field mode 2 are safety-related.
– The CNC or safety system provides the signal. It is only absolutely necessary to con-
– When driven via relay contacts it is the user's responsibility to apply an appropriate
The inputs for protected field mode 1 and protected field mode 2 can be switched directly
via the 24 VDC supply. In this case, both inputs should be linked. Only the following pro-
tected field modes are possible:
– "Standard" protected field mode (switch open, both inputs = "0")
– "Box bending with back gauge" protected field mode (switch closed, both inputs = "1")
Fig.: Protected field mode 1/2 directly at the 24 V DC supply
}
The input to acknowledge the specified protected field mode can be switched directly via
the 24 VDC supply.
Function test
}
When the wiring is complete the protective equipment will need to undergo a function
test.
Operating Manual PSENvip RL D P Set
1001641-EN-09
nect the inputs to a safety system if communication is needed for tool detection.
safety concept.
Protected field mode 1
Protected field mode 2
NOTICE
The acknowledgement button for the protected field mode must be posi-
tioned outside the danger zone in such a way that the operator can see all
of the danger zone.
INFORMATION
To perform the function test, follow the procedure described in Chapter 7,
"Commissioning", section entitled "Function test of the safety device".
X1
3
4
24 V DC
| 58