Diagnostics and Troubleshooting
9.3
DIAGNOSTICS menu
The DIAGNOSTICS menu provides Pilz service staff with further information to help them
identify faults.
}
Press the <MODE> key.
}
Using the keys
}
Press the <ENTER> key to open the DIAGNOSTICS menu.
Fig.: Diagnostic data on the display
}
1: Diagnostic block
}
2: Diagnostic data
}
3: Data in hex
9.3.1
Diagnostic blocks and diagnostic data
The System Data diagnostic block contains the following diagnostic data:
}
Type: The type of PSENvip
}
SW Version: The software version of PSENvip
}
Device Data: Device data
}
Configuration: Overrun
}
Tool Data: Tool data
}
Error Statistic: Information on the error rate
}
Thresholds: Information on the optical system
}
Mod Limits: Information on the optical system
}
Run Statistic: Information on the optical system
}
Adjust Statistic: Information on the optical system
The Error Data diagnostic block contains the following diagnostic data:
}
Error stack with the last 10 entries
Operating Manual PSENvip RL D P Set
1001641-EN-09
, select the DIAGNOSTICS menu.
SYSTEM OK OSSD OFF
À
System Data:
Á
Variant:
Â
0058 3601
DIAGNOSTICS
A000