Commissioning
Evaluation of the "Out of range" message:
Note that the Out of range message is for information only.
The guide frame indicates the maximum possible protected field based on the press over-
run. The maximum possible protected field is needed in the event of a maximum overrun of
14 mm. If the tool centre point is at the lower end of the range bar in the event of a max-
imum overrun (see
message appears, this can lead to false stops during operation. In this case you must cor-
rect the adjustment.
If you comply with the specifications for the required protected field size and the overrun is
less than 14 mm, the adjustment can also be completed when the Out of range message
appears.
Note the following specifications regarding the required protected field, based on the over-
run.
Fig.: Required protected field based on the overrun
Legend
[1]
Overrun
14 mm
12 mm
10 mm
8 mm
6 mm
Operating Manual PSENvip RL D P Set
1001641-EN-09
Make adjustment during tool change [
Tool detection
44 mm
Height of the protected field
(Overrun + 6 mm)
20 mm
(maximum protected field)
18 mm
16 mm
14 mm
12 mm
78]) and the Out of range
[1]
Colour of protected field
(see diagram)
White
Blue
Green
Yellow
Brown