Function description
}
5
– The safety system reflects the tool class transmitted by the PSENvip.
– Tool class PLC -> PSENvip Bit 1/2 = 0 or 1, depending on the tool class
Tool class PLC -> PSENvip Bit 1
Tool class PLC -> PSENvip Bit 2
}
6
The PSENvip ends communication.
All outputs are set = 0:
– Activate = 0
– Acknowledge PSENvip -> PLC = 0
– Tool class PSENvip -> PLC Bit 1 = 0
– Tool class PSENvip -> PLC Bit 2 = 0
}
7
– The safety system ends communication.
– Tool class PLC -> PSENvip Bit 1/2 = 0 or 1, depending on the original status
4.5

Protected field modes

Four protected field modes are available for adapting to different bending functions:
}
Full protected field: Standard press stroke
}
Reduced protected field:
– Box bending press stroke
– Back gauge press stroke
– Box bending with back gauge press stroke
Use of the protected field modes depends on the tool class. Not all protected field modes
can be selected with tool class 2 and 3.
Operating Manual PSENvip RL D P Set
1001641-EN-09
PLC Ready = 1/0 pulse edge
INFORMATION
The requirements of the user program in the safety system are described
under "System Connections".
Tool class
1
2
0
1
1
0
3
1
1
| 36