Function description
}
Protected field mode 1/protected field mode 2
Two safe inputs for setting the protected field mode. The CNC or programmable safety
system provides the signal. It is only absolutely necessary to connect the inputs to a pro-
grammable safety system if communication is needed for tool detection.
Protected field
mode
1
0
1
0
1
4.4.3.2

Outputs

}
OSSD1/OSSD2 in accordance with EN 61496-1, type 4
Two safe outputs that signal the status of the protected field:
OSSD = 1: Protected field clear
OSSD = 0: Protected field broken
}
Mute1/Mute2 in accordance with EN 61496-1, type 4
Two safe outputs that signal the dynamic muting
Mute1/Mute2 = 1: no dynamic muting
Mute1/Mute2 = 0: dynamic muting active
Operating Manual PSENvip RL D P Set
1001641-EN-09
Bending function
2
0
Standard
0
Box bending
1
Bending with back gauge
1
Box bending with back gauge
INFORMATION
The inputs for protected field mode have another function during the system
status TEST. They are used for communication with the programmable
safety system. See "Communication with a programmable safety system" in
this section.
INFORMATION
The outputs Mute1/Mute2 have another function during the system status
TEST. They are used for communication with the safety system. See "Com-
munication with a safety system" in this section.
INFORMATION
For details of the output behaviour during a press stroke please refer also to
the section entitled "System cycle", in this chapter.