Function description
Fig.: Size of the protected field
The two following sections explain the basic mode of action of the protected field during a
press stroke (interrupted and uninterrupted).
4.2.1

Dynamic muting

An advance measuring field is located below the protected field. If is interrupted, the dy-
namic muting is started. Dynamic muting ensures that the danger zone between upper tool
and workpiece is monitored up to a remaining gap of 6 mm during the downward movement
of the press.
The distance of the advance measuring field to the lower edge of the protected field is con-
stant. The distance to the top edge of the protected field varies according to the length of
the overrun.
Fig.: Distance of advance measuring field from protected field
Operating Manual PSENvip RL D P Set
1001641-EN-09
1 mm
44 mm
INFORMATION
Please note that the central segments are 1 mm behind the bending line.
With box bending you must ensure that the side panels of the box do not
encroach into this area.
INFORMATION
The cycle of a press stroke with the corresponding inputs and outputs is ex-
plained in this chapter, in the section entitled "System cycle".
overrun 2 mm
overrun 14 mm
protected field
advance measuring field
| 22