Wiring
PIn No. Designation
Shield
*) Used in communication between PSENvip and safety system.
Pin assignment of M12 connector X2 on the receiver
PIn No. Designation
1
2
3
4
5
6
7
8
Shield
*) Used in communication between PSENvip and safety system.
The two safety outputs OSSD1 and OSSD2 must be connected separately to the machine's
programmable safety system. OSSD1 and OSSD2 must not be connected.
Fig.: Correct and incorrect connection of OSSD1 and OSSD2
Operating Manual PSENvip RL D P Set
1001641-EN-09
Cable shield
Acknowledge PSENvip -
> PLC *)
Power Off
PLC Ready *)
Acknowledgement
System-Init
OSSD2
Mute2
Tool class PSENvip ->
PLC Bit 2 *)
0 V
TRM_SYNC
Cable shield
OSSD1
OSSD2
Description
Description
Output, confirm validity of tool class
Input, activates setup mode
Input, safety system signals that it is
ready for communication
Input, acknowledges initiation of a
press stroke with reduced protected
field
Input, the press is at top dead centre
Output, OSSD2
Output, dynamic muting
Output, sends tool class Bit 2 to safety
system
Input, 0 V supply voltage
Output, signal to control the intensity of
the transmitter's light source
OSSD1
OSSD2
Colour
Colour
White
Brown
Green
Yellow
Grey
Pink
Blue
Red