Pilz PSENvip RL D P Set Operating Manual page 103

Table of Contents

Advertisement

Technical details
Inputs on the receiver
Number
Galvanic isolation
Signal level at "0"
Signal level at "1"
Input current
Recognition time
Outputs on the receiver
Number of positive-switching single-pole semicon-
ductor outputs
Galvanic isolation
Output current at "1"
Permitted range
Short circuit protection
Min. pulse width at "0" signal (off time)
Max. cable length with cable cross section 0.25 mm
OSSD/Mute in accordance with EN 61496-1, type 4
Signal level at "0"
Signal level at "1"
Residual current at "0" signal
Duration of on and off time during self test
Max. cable resistance for detection of shorts
between contacts
Max. capacitive load
Max. inductive load
Transmitter synchronisation
Max. capacitive load
Environmental data
Protection type (EN 60529)
Ambient temperature
(EN 60068-2-14)
Storage temperature
(EN 60068-2-1, EN 60068-2-2)
Climatic suitability
(EN 60068-2-78)
Condensation
Vibration
Operating Manual PSENvip RL D P Set
1001641-EN-09
5
No
-3 V ... +5 VDC
+15 V ... +30 VDC
Typ. 6 mA
Min. 100 ms
8
No
Max. 0.25 A at 24 VDC
0 ... 0.32 A
Electronic
100 ms
2
150 m
0 VDC (-3 V ... 2 V in accordance with EN 61496)
UB - 1 VDC (11 V ... 30 V in accordance with EN
61496)
Max. 1 mA (<2 mA in accordance with EN 61496)
40 µs
16 Ohm
20 nF for R
> 48 ohms with rated voltage
L
0.5 H
500 nF
IP54
0 ℃ ... 50 ℃
-35 ℃ ... 70 ℃
93 % rel. h. at 40 °C
Not permitted
Frequency range: 10 Hz ... 55 Hz