7.2.3

Configure braking ramp monitoring

Braking ramp monitoring is only relevant for the productive version.
To monitor the braking ramp the press overruns must be measured at various speeds; i.e.
an overrun profile must be created.
An Excel tool can be used to determine the monitoring curve (worst case curve) from the
measured values. The determined monitoring curve can be used for both braking ramp
monitoring by the PAS4000 user program and for braking ramp monitoring by PSENvip.
When the certified blocks for the PAS4000 library are used, the Excel tool can be used to
calculated the required base values for braking ramp monitoring.
The current Excel tool is available in the download area of the Pilz homepage. It is a
packed file (ZIP file). The download is only available for registered users. Unregistered
users can register free of charge. A valid E-mail address is required for registration.
Name of the ZIP file:
}
PSENvip_OverrunCalculationTool_for_RampMonitoring_<Version>.zip
(e.g. PSENvip_OverrunCalculationTool_for_RampMonitoring_1_0_0.zip)
Contents of the ZIP file:
}
– Excel tool
– Operating manual
7.2.4

Test the function of the safeguard

Before operating the press brake, the safeguard must be subjected to a function test. The
function test includes:
Detection of objects
}
Overrun measurement
}
The function test is carried out using a test piece in accordance with EN 12622, Annex G.
Prerequisites
The press brake is fully configured with the upper tool (maximum weight).
}
Transmitter and receiver are correctly aligned and ready for operation.
}
The press brake is at top dead centre.
}
Standard protected field mode is selected.
}
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
PSENvip_OverrunCalculationTool_for_RampMonitoring_<Version>.xls
(e.g. PSENvip_OverrunCalculationTool_for_RampMonitoring_1_0_0.xls)
PSENvip_Operat_Man_OverrunCalculationTool_for_RampMonitoring_1003525-
<Language>-<Version>.pdf
(e.g. PSENvip_Operat_Man_OverrunCalculationTool_for_RampMonitoring_1003525-
DE-01.pdf)