Kinematic Continuous
Notice:
Remember, both receivers must collect data from the same satellites at
the same data recording rate and with identical elevation mask angles.
www.javad.com
Kinematic continuous measuring allows the Rover to move without
having to stand still, record data, move to another point, and do it all
again.
If the surveyor knows the coordinates of the starting point, the rover
will not need to be initialized. This procedure (i.e., determination of the
ambiguity parameters) is carried out while the rover is moving and is
called "on-the-fly ambiguity resolution". Furthermore, if loss of lock
occurs (such as, an obstruction that prevents a clear view of the sky), the
receiver will also be re-initialized on-the-fly.
After the measuring completes, data the receivers collect can be
downloaded onto a computer and processed using post-processing
software (for example, Ensemble).
1.Using PCView, configure and set up the Base station as described in
"Static Measuring" on page 3-6.
2.Using PCView, click Configuration->Receiver
->MinPad, and configure the Rover with the following parameters,
then click Apply (Figure 3-6 on page 3-10):
• FN Key Mode, Occupation Mode Switch – enable
• Initial data collection dynamic mode,
Kinematic – enable
3.Click the Advanced tab, then the Loop Management tab, and
configure the Rover with the following parameters, then click Apply
(Figure 3-7):
• Enable Common tracking – enable
S E T U P A N D M E A S U R I N G
Measuring with the Prego
Prego Operator's Manual 3-11