Use PCView to Clear NVRAM

Changing Receiver Modes

The Prego receiver has four modes, two information modes and two power
modes:
• Normal Mode
• Extended Information Mode
• Sleep Mode
• Zero Power Mode
See "Information Modes" on page 4-5 for a description of Normal Mode and
Extended Information Mode.
www.javad.com
2. Press and hold the FN key.
3. Press and hold the power key for about one second. Release the power
key while continuing to hold the FN key.
4. Wait until both LEDs are green
5. Wait until both LEDs blink orange.
6. Release the FN key while LEDs blink orange.
1. Connect your receiver and computer. See "Connecting the Prego and a
Computer" on page 2-4 for this procedure.
2. Click Tools->Clear NVRAM (Figure 4-16). The REC LED rapidly
flashes green and red; the STAT LED flashes just red.
3. The receiver will automatically disconnect once the NVRAM is
cleared.
Figure 4-16. Tools->Clear NVRAM