Javad Prego Operator's Manual page 131

Table of Contents

Advertisement

Output interval for
RTCM correction
data
Elevation mask
Multi-base DGPS
RTK
Correction format
RTCM message type
Reverse RTK
Ambiguity initialize
Baseline Length
Initialize time
Output interval for
CMR/RTCM
Elevation
Process interval
Latency
Raw Data logging
Status
Results
www.javad.com
Table B-1. Prego Specifications
Component
1, 5, 10, 20 (5 to 20 Hz is optional)
0 to 90 deg (independent with data logging
Differential correction select mode: Nearest, Mix,
Best (optional)
CMR2/CMR+ (Trimble compatible), RTCM
SC104 Ver 2.2 and 2.3
3, 18, 19, 20, 21, 22 user selectable
Will be available in future
OTF (L1, L1/L2)
Up to 50km in the morning and evening. Up to 32
km at noon.
5 seconds to 10 min depending on the base line
length and multipath conditions
1, 5, 10, 20 Hz (5 to 20 Hz is optional)
0 to 90 deg (independent with data logging)
1, 5, 10, 20 Hz (5 to 20 Hz is optional)
Delay mode: 20 msec–20 sec (depends on latency
which receives corrections data from base receiver).
Extrapolation: 20–30 msec
The receiver can record the raw data at another
interval while RTK operation.
Fix, Float, DOP, Data Link Status, Modem Latency,
Common sats, Percentage of the fixing
RTK coordinates, HRMS, VRMS, Covariance
Matrix