35

Load factory settings

Before you configure the device to its factory settings, you should note the following:
• Save your configuration first. After restoring the factory settings, all of your settings/changes will be
deleted.
• The IP address of the device is reset to the original IP address (192.168.0.100).
You may also need to modify the network settings of the configuration PC accordingly.
• The device password is reset to its individual default password. The default password can be found
on the back of the unit.
• No USB stick/storage medium should be connected to the device.
Execution:
1.
a. Switch on the mbNET or
b. if the mbNET is ready for operation, press the Reset button.
2. When the LED Rdy flashes (green), turn the key switch - with
the red key - to the switch position RST and hold this key posi-
tion.
The key position RST has only a button function => you have to
hold the key in this position.
3. When LED Fc3 is flashing (orange), release the key.
When both the Pwr and Rdy LEDs light up, the mbNET is reset to its
„factory settings at the time of delivery" and can/must be reconfigured.
NO T I CE
NO T I CE
Load factory settings | Page 321 of 324