MB Connect Line mbNET.rokey RKH 210 Manual page 227

Hide thumbs Also See for mbNET.rokey RKH 210:
Table of Contents

Advertisement

Designation
Description
Active
Check box for enabling/disabling this function.
Connection name
In the text box, enter a name for the connection.
Connection type
Selection field for the connection type
Link connection
Selection field for when or under which conditions the connection should be started.
- Connect while enable Key Switch position "Online (ONL)"
- Wait for incoming connection
If one of the active connection options was selected to establish the connection, then this mbNET is in "client
mode" and will be referred to as "client" in the further documentation.
The mbNET on the other side is in "waiting position".
One of the routers must be in "wait mode"!
Designation
Description
Remote mainte-
You can only choose from::
nance active on
- Key switch (REM)
The Link connection and Remote maintenance active on functions are part of the concept of 2-level
security.
A description of the 2-level security can be found after this table.
Peer addresse (IP,
Here, in the case of the OpenVPN client, the public IP address or DynDNS name (ex-
DNS)
ample: 0987654321@mbnet.mymbnet.biz) of the OpenVPN server must be entered.
Disconnect con-
Enter the time after which an existing connection is terminated if no data packets are
nection after inac-
transmitted during this time. If nothing is entered, or if the entry is "0", the connection
tivity [s]
remains.
Click the Next button to continue the configuration.
• Router - Router connection
• Client router connection
NO T I CE
NO T I CE
NO T I C E
VPN | Page 227 of 324