General Data
Performance data
Voltage
V (DC)
Current consumption
Dissipated power
Random Access Memory 512 MB
Processor
IP Protection class
Area of use
Temperature (operating)
Temperature (storage)
Humidity
Real-time clock
Dimensions (max.)
Weight (max.)
Housing/material
Installation
Page 22 von 324 | V 7.2.0 - en | Aug 25
Comment
Previous version: V 1.0 from Nov. 2
Correction of the current consumption: old = 1300 mA => new = 500mA
Add the performance data for new LTE module, for devices with hardware
version HW04.
Add processor performance data.
Adding the transmission power for radio modules.
Update / change of the encryption algorithms.
Add the performance data for new LTE module, for devices with hardware
version from HW05.
Change of "Target region" for LTE AT&T modems for devices from hard-
ware version HW 05: "Verizon" was removed.
10 – 30 V DC (ext. power supply or SELV power supply, 10-30 V DC, max. 40
A)
max. 500 mA @ 24 V
max. 6 W
Devices with hardware version HW03: ARM Cortex
Devices from hardware version HW04: ARM Cortex
IP 30*
* at full occupancy of all connections and interfaces. Alternatively, unused interfaces can
Dry environment
-40 – +75 °C
-40 – +85 °C
0 – 95% non-condensing
In the event of a power failure, the date and time are maintained for up to 7
days (depending on the ambient temperature).
48 mm x 137 mm x 140 mm (W x D x H)
650 g
Metal
DIN-top hat rail mounting