Alarm Management

The mbNET Alarm Management provides the following functions:
• Status query (1/0) of the four digital inputs (I1 - I4) with subsequent action:
° Send an Email
° Perform a device Restart
° Send an SMS
° Send an Internet-SMS
• Use Multiplex Inputs - an action specification (number) can be transmitted serially by the user via the
inputs (2 - 4). A selected action is carried out with a falling edge at STROBE.
° Send an Email
° Perform a device Restart
° Send an SMS
° Send an Internet-SMS
• independent switching of the two digital outputs for specific events:
° On in the event of a device fault
° On in the event of an active internet connection
° On in the event of an active VPN connection
° On in the event of an active user portal connection
° Off