Figure 4-45. SCSI Cable from the SCA Hard Disk Interface
SCSI cable
4. Pick up the power supply with both hands and align the power supply with the guide
rails. Slide the power supply forward on the guide rails to seat it in the I/O board
connectors.
5. Insert and alternately tighten the two power supply jack screws, as shown in Figure
4-44 on the previous page. Take care to align the rear face of the power supply to the
rear wall of the mainframe chassis so that the jack screws will mate properly. Continue
tightening until the screws stop.
6. Secure the bus bars to the system board with either the four bus bar thumbscrews on
the J5xxx workstation, or the five bus bar thumbscrews on the J7xxx. Figure 4-46
shows these thumbscrews on the J5xxx workstation.
NOTE
Failure to sufficiently tighten the bus bar thumbscrews will cause the power
supply to not activate.
Figure 4-46. Bus Bar Thumbscrews
Chapter 4
Field Replaceable Units (FRUs)
FRU Removal and Replacement
131