Peripheral Unit Dimensions; Peripheral Unit Environment - Mitel 3300 ICP Hardware User's Manual

Integrated communications platform
Table of Contents

Advertisement

3300 ICP Hardware User Guide
-
A ground connector.

Peripheral Unit Dimensions

Height
Width
Depth
Weight

Peripheral Unit Environment

Condition
Temperature
Humidity
Vibration
Mechanical Stress
Horizontal Transportation
Impact Stress
Condition
Temperature
Humidity
Maximum Heat Dissipation
- fully loaded (see Note)
Air Flow
Radiated Emissions
Conducted Emissions
Acoustic Emissions
Static Discharge
Lightning Surge
Induction (Normal)
74
Physical Dimensions
19 inches (48.0 cm)
18 inches (45.8 cm)
16.5 inches (42.0 cm)
95 lbs (43.2 kg)
Storage Environment
Specification
-40º to 150ºF (-40º to 66ºC)
5-95% Relative Humidity, non-condensing
0.5 g, 5 to 100 Hz, any orthogonal axis
1.5 g, 100 to 500 Hz, any orthogonal axis
One 20.3 cm (8 inch) drop, each edge and corner adjacent to the rest
face – unpackaged
One shock pulse applied on each face perpendicular to the direction
of motion of the transporting vehicle; the shock pulse is a half-sine
acceleration 30 g peak, 20 ms duration
Operational Environment
Specification
32º to122ºF (0º to 50ºC)
5-95% Relative Humidity, non-condensing
724 BTUs per hour
150 cubic feet per minute at maximum output of the fans
The system meets Class A limits as outlined in FCC Rules, Part 15,
Subpart J
The system meets Class A limits as outlined in FCC Rules, Part 15,
Subpart J, and complies with conducted emissions standards as
outlined in BS800
Maximum 50 dBA continuous, 75 dB intermittent (<10% duty cycle)
Withstands 50 discharges of each polarity through a 10 k resistor
connected to a 60 pF capacitor charged to 20 kV, and 20 discharges
of each polarity through 500 ohm resistor connected to a 100 pF
capacitor charged to 10 kV
2.5 kV peak, with a maximum rise time of 2 µs and minimum decay
time of 10 µs applied to power lead terminals, and 800 V peak with a
maximum rise time of 10 ms and minimum decay time of 560 ms
applied to outside plant interface terminals
50 Vrms at 60 Hz, open circuit, longitudinal mode (Tip and Ring to
ground)
Release 3.3