700 User System without Compression
This system uses:
One 300 MHz RTC
One 300 MHz E2T
One 128 Channel Echo Canceller
Two Dual FIMs
Two DSP Modules (21061/21161) for telecom support
This provides:
Eight DSP devices for telecom functions
128 channels of Echo Cancellation
Two External FIM connections
Four ASU connections (CIM ports)
The four external FIM connections are for providing connectivity for up to four Peripheral Units
or up to eight NSUs. Note that there are two T1/E1 links per NSU.