Digital Service Unit Dimensions; Digital Service Unit Environment - Mitel 3300 ICP Hardware User's Manual

Integrated communications platform
Table of Contents

Advertisement

Fiber Interface Modules (FIMs): The DSU cabinet holds up to two fiber interface modules
(FIMs). Each FIM supports two DSU cards; the FIM installed in Shelf 1, slot 1 supports
the DSU cards in Shelf 1, slots 2 and 3. The FIM in Shelf 1, slot 6 supports the DSU cards
in Shelf 1, slots 4 and 5.
DSU Cards: The DSU cabinet holds up to four DSU cards. These are intelligent cards that
provide specialized digital functions. The DSU cards are installed in Shelf 1, slots 2 to 5.
DSU Backplane: The backplane holds up to four DSU cards, two fiber interface modules,
two peripheral resource cards, the power supply cable, and two Maintenance Terminal
ports. The four DSU cards are split into pairs (each pair with a FIM, Peripheral Resource
card, and maintenance port). The following switches and connectors are located on the
DSU backplane (rear panel):
-
A power on/off switch
-
A small red sliding switch for selecting the input power source. The switch can be set
to either 115 Vac, 60 Hz or 230 Vac, 50 Hz.
-
A 3-conductor male receptacle to connect AC power
-
A sliding panel for the Tx and Rx fiber optic cables
-
Two RS-232 Maintenance Terminal ports
-
A 3 inch wide x 4 inch high (7.6 cm x 10.2 cm) metal box projecting from the middle
of the panel. The box holds up to four CEPT or DS1 Interface Assemblies.
CAUTION: Do not connect any devices to the female power receptacle.

Digital Service Unit Dimensions

Height
Width
Depth
Weight

Digital Service Unit Environment

Condition
Temperature
Humidity
Vibration
Mechanical Stress
Horizontal Transportation
Impact Stress
Physical Dimensions
19 inches (48.0 cm)
9 inches (22.9 cm)
16.5 inches (42.0 cm)
40 lbs (18.0 kg)
Storage Environment
Specification
-40º to 150ºF (-40º to 66ºC)
5-95% Relative Humidity, non-condensing
0.5 g, 5 to 100 Hz, any orthogonal axis
1.5 g, 100 to 500 Hz, any orthogonal axis
One 20.3 cm (8 inch) drop, each edge and corner adjacent to the rest
face – unpackaged
One shock pulse applied on each face perpendicular to the direction of
motion of the transporting vehicle; the shock pulse is a half-sine
acceleration 30 g peak, 20 ms duration
Release 3.3
Specifications
89

Advertisement

Table of Contents
loading