Protective ground to ground the chassis.
Power connector.
Note: UK BRI will drive power to the BRI circuits; the NA BRI will not.

3300 BRI NSU Protocols

Fifteen interfaces are programmed for line support in the NA product and line or trunk support
in the UK version. The 3300 BRI NSU protocols are
Euro-ISDN 2B+D, Basic Rate Interface
North American National ISDN-1
North American National ISDN-2.

Mitel Networks 3300 NSU Dimensions

Height
Width
Depth
Weight

3300 NSU Environment

Condition
Specification
Temperature
-40º to 140ºF (-40º to +60ºC)
Humidity
15-95% Relative Humidity, non-condensing
Vibration
0.5 g, 7 to 100 Hz, any orthogonal axis
1.5 g, 100 to 500 Hz, any orthogonal axis
Mechanical Stress
One 15.3 cm (6 in.) drop, each edge and corner adjacent to the rest face –
unpackaged
One 76.2 cm (30 in.) drop, each edge and corner packaged in cardboard &
foam.
Physical Dimensions
1.75 in. (4.454 cm) (1 U)
17.75 in. (45.1 cm) (19" rack mountable)
15.5 in. (39.4 cm)
9.41 lb (4.27 kg)
Storage Environment