Mitel 3300 ICP Hardware User's Manual page 196

Integrated communications platform
Table of Contents

Advertisement

3300 ICP Hardware User Guide
250 User to 700 User System - 32 Compression Channels
250 user system (Release 3.0/3.1 chassis) upgrade to 700 user system with 32 channels of
compression.
This system uses the following existing modules:
One RTC (3.0/3.1 133 MHz; 3.2/3.3 300 MHz)
One E2T (3.0/3.1 133 MHz; 3.2/3.3 300 MHz)
One Dual FIM Module
One DSP Module (21061/21161) for telecom support
One 64 Channel Echo Canceller
Add the following modules:
One DSP Module (21061/21161) for telecom support
One DSP Module (21161) for 32 compression channels
One Dual FIM Module
One 64 Channel Echo Canceller
Note: A second 64-channel Echo Canceller can be added, or the existing 64-channel
Echo Canceller can be replaced by a 128-channel Echo Canceller. If you choose to add
a second Echo Canceller, the controller must be operating on version 3.2 software. The
3.0/3.1 software does not support two 64 echo cancellers.
This provides:
Eight DSP devices for telecom functions
32 channels of compression
30 Voice Mail Ports
128 channels of Echo Cancellation
Four External FIM connections
Four ASU connections (CIM ports)
The four external FIM connections are for providing connectivity for up to four Peripheral Units
or up to eight NSUs.
Note that there are two T1/E1 links per NSU.
To upgrade a 250 user system to a 700 user system with 32 channels of compression:
1. Remove the cover.
2. Install the new Dual FIM Modules (slot 2).
3. Install the new 21161 DSP Modules (slot 7 and slot 4).
4. Install the 64 Echo Canceller Module (slot 6).
5. Replace the cover.
188
Release 3.3

Advertisement

Table of Contents
loading

Table of Contents