Hardware; Troubleshoot The 3300 Controller - Mitel 3300 ICP Hardware User's Manual

Integrated communications platform
Table of Contents

Advertisement

Troubleshooting

Hardware

Troubleshoot the 3300 Controller

Note: The visual indications on the FIM, Alarm, CIM, and LAN Ethernet port LEDs are the same
for the 100- and 250/700-user variants.
FIM LED State
On
Off
Flashing
Note: If a remote MFC Status LED is OFF, go to the FIM and check its local FIM Status LED. If it is
ON, the fiber cable may be faulty.
Alarm
Critical
Major
Minor
Alarms OFF
Integrated Voice Mail
Major
Minor
Fiber Interface Module LEDs
Meaning for Local, Upper and Remote, and Lower FIM
In frame synchronization.
Power off or held in reset.
Out of synchronization, or Tx or Rx cables might be reversed.
Alarms LEDs
State
LED
Meaning
On
Red
Indicates that customer service has been lost and immediate
maintenance is required. A critical alarm invokes system fail
transfer if enabled. This LED will be on during POR (power on
reset) or when the INIT switch is activated (resets all boards).
Off
No alarm.
On
Red
Indicates that service has degraded beyond predetermined
thresholds. This LED is also on when there is a critical Alarm.
This LED will be on during POR or INIT switch active.
Off
No alarm.
On
Red
Indicates the presence of a minor malfunction in the system.
A minor alarm is raised whenever the system is not fully
operational. This LED is also on when there is a critical Alarm.
This LED will be on during POR or INIT switch active.
Off
No alarm.
On
Green
Alarm is on but silenced. Silence state is toggled by the
Remove Alarms ON/OFF switch.
On
Green
During POR or INIT switch active.
Off
Alarm is audible.
Off
During power-up state.
On
Red
The voice mail is not functioning or disk space is at 95%.
Off
No alarm.
On
Red
Voice mail disk space is at 90%.
Off
No alarm.
Release 3.3
Troubleshooting
237