3300 ICP Hardware User Guide
SX-2000 LIGHT to 3300 ICP
To upgrade SX-2000 LIGHT hardware for 3300 control:
•
384 port Peripheral - main control replacement
•
DSU - main control replacement
•
Peripheral cards - DNIC Line, ONS CLASS, ONS Line, LS/GS Trk, E&M Tie Trk, OPS
Line, DID/Loop Tie
•
DSU cards - T1 (DS1) Formatter, CEPT Interface, ISDN PRI, E1/T1 Dig Trk Formatter, E1
R2, 6CCT BRI, 15CCT BRI
•
If existing capacity is greater than that of the 3300 ICP, the conversion will fail. See the
capacity table for the 3300 ICP.
The SX-2000 LIGHT Digital Services Unit (DSU) cabinet provides digital trunk capability, and
the SX-2000 LIGHT peripheral cabinet provides connectivity for analog trunks, analog
telephones, and Mitel DNI devices. Both cabinet types can be connected to the 3300 Controller
by using multi-mode fiber connections.
The DSU cabinet supports BRI, PRI, T1/D4, MSDN/DPNSS, and DASS II trunks.
The peripheral cabinet supports the following analog trunks:
•
Analog CO trunks
•
E&M trunks
•
Direct Inward Dial and Tie Trunks.
The peripheral cabinet also supports the following DNI telephones and devices:
•
SUPERSET 401
•
SUPERSET 401+
•
SUPERSET 410
•
SUPERSET 420
•
SUPERSET 430
•
SUPERSET 4001
•
SUPERSET 4015
•
SUPERSET 4025
•
SUPERSET 4125
•
SUPERSET 4150
•
SUPERCONSOLE 1000.
For additional information, refer to SX-2000 technical documentation.
194
Release 3.3