LS Trunk Signaling Protocols (3300 Universal ASU)
North America (NA)
Latin America (LA)
United Kingdom (UK)
United Kingdom (UK)
United Kingdom (UK)
Europe (EU)
LS Trunk Parameters (3300 Universal ASU)
Trunk Functions
Input Impedance
Balance Impedance
Min. operating loop current
Max operating loop current
Loop Current Limit
Ring detector Threshold
Dummy Ringer load
Reversal detector
Loop detect for CO disc. (no
battery)
Meter Pulse Detection
Note: The NA variant is designed according to the performance standard EIA/TIA 464C. The UK
Variant is designed in accordance with CTR21, but has design parameters favoring towards BS6305
and BS6450. The EU variant is designed in accordance with CTR21.

Music On Hold (3300 Universal ASU only)

Four physical ports are supported for Music on Hold (MOH) on the 3300 Universal ASU.
The MOH interface supports the following features:
600 Ohm input impedance
Signal level overload protection as mandated by FCC part 68 on encoded analog content
Dry Tip/Ring interface (no battery)
Always active input (no external control required or provided).
70
LS Trunk Signaling Supported Protocols
ASU Variant
Parameters for NA/LA
600 Ohms
600 Ohms for short loop
application
350R + (1000R// .21uF) for
long loops
18mA
100mA
None
30Vrms
10kOhms + 2.2uF (NA)
65Ohms + 2.2uF (LA)
Detects CO battery polarity
< 2V across Tip and Ring
None
TIA/EIA-464-B
UK Subscriber / Subsidiary Loop
UK Loop Start Disconnect Clear
CTR-21
370R + (620R//310uF) (UK)
270R + (750R//150uF) (EU)
370R + (620R//310uF) (UK) 270R
+ (750R//150uF) (EU) for all loop
lengths
18mA
60mA
60mA
20Vrms
10kOhms + 2.2uF
Detects CO battery polarity
< 2V across Tip and Ring
50Hz longitudinal (UK)
None (EU)