Implementation
In the loss plans, positive values are losses and negative values are gains. The losses are
shown in one direction only (outgoing, from the specified port type); the reverse path loss can
be found by using a second look up (e.g. In North America, OPS to WAN is a -3dB gain and
WAN to OPS is a 9dB loss).
Note: Mitel Networks digital telephones meet the following ITU-T recommended loudness rating:
- Send Loudness Rating (SLR) 8 dB - Receive Loudness Rating (RLR) 2 dB.
In interpreting loss plans, refer to the following legend:
Port
IP On Premise Station
On Premise Station
IP Off Premise Station
Off Premise Station
Digital Station
Wide Area Network
Digital CO Trunk
IP Analog CO Trunk
IP Analog CO Trunk (short)
Analog CO Trunk
Analog CO Trunk (short)
Analog Tie Trunk
Note: iONS, iACO, and iACOs apply to the new analog interface designs that comply with the IP
connected half-channel loss plan. The first instances of these is on the 3300 ASU.
12
Loss and Level Requirements Specifications
Requirement Document
ACIF S002, S003
CS03, T520, T512
TBR21, ST13
TBR21
TBR21
TBR21
TNA-102, PTC-207, PTC-217
TIA/EIA 464-C, TIA/EIA TSB 116
TBR21
TBR21
BTR1050, BTR1080, BTR 1181, NCOP(86)42 and BS6450 Pt 4
Release 3.3
Abbreviation
iONS
ONS
iOPS
OPS
DGS
WAN
DCO
iACO
iACOs
ACO
ACOs
ATT