Output Voltage
+3.3 +/- 1.5%
+5.0V +/- 1%
+12.0V +/- 7%
3300 Controller PCB Interfaces
Connector
Function
RS-232
DB9
EIDE
40 pin male
10/100
8-pin Mod- jack
Ethernet
CIM
8-pin Mod- jack
Alarm Drive DB9
56
Output Power
Max Current
30.0A
8.0A (Total power of 3.3V and 5.0V not to exceed 100W)
3.0A (Hard Disk Drive)
PCB (Printed Circuit Board) Interfaces
Type
Quantity
2
1
4 (2 in 100
Controller)
4 (2 in 100
Controller)
1
Release 3.3
Signals
Txd, Rxd, (RTS), (CTS),
(DTR), (CD), DSR, Gnd
(parenthesis indicates
operational function,
dependent upon application)
Internal Hard Disk Drive
TxP, TxN, RxP, RxN
(Cross-over DX connections)
Txlink, Rxlink
(all differential pairs)
Contact closures, Critical,
Major, Minor alarms
Comments
DCE pinout.
Female style.
Supports rates to 115K.
Default setting 9600, 8
bits, No Parity, 1 Stop-bit,
Txd, Rxd, Gnd
Internal to box. (On RTC)
User side pinout
Pinout is based on
standard IT cable pairs.
DB9 connection (female
connection)